Issue

Intersection of 3 walls changed when opening 9 file.
picture.JPG

Cause

In ArchiCAD 10 a new feature (the Priority-based Wall Intersections) enables the correct Floor Plan intersection of Composite and Complex (Profile) Walls. You can assign intersection priority to wall elements or individual wall skins (through composite attributes) or wall components (through profile attributes). Wall skins and components intersect with each other based on their intersection priority, if assigned, or based on the intersection priority of the Wall as a whole. These two types of Walls will also intersect perfectly according to the following rules:

As a result of implementing priority-based wall connections in AC 10 certain intersections which were created in AC9 (or older versions) and which seemed to be perfect might change when opened in AC10. In the above example no priority was set to the walls.

Solution

Workaround: Use "Modify Wall" to move reference lines and Wall and Skin Priorities to correct those special intersections.